aboutsummaryrefslogtreecommitdiffstats
path: root/src/com/jsyn/unitgen/SchmidtTrigger.java
diff options
context:
space:
mode:
Diffstat (limited to 'src/com/jsyn/unitgen/SchmidtTrigger.java')
-rw-r--r--src/com/jsyn/unitgen/SchmidtTrigger.java83
1 files changed, 0 insertions, 83 deletions
diff --git a/src/com/jsyn/unitgen/SchmidtTrigger.java b/src/com/jsyn/unitgen/SchmidtTrigger.java
deleted file mode 100644
index 64129ff..0000000
--- a/src/com/jsyn/unitgen/SchmidtTrigger.java
+++ /dev/null
@@ -1,83 +0,0 @@
-/*
- * Copyright 2009 Phil Burk, Mobileer Inc
- *
- * Licensed under the Apache License, Version 2.0 (the "License");
- * you may not use this file except in compliance with the License.
- * You may obtain a copy of the License at
- *
- * http://www.apache.org/licenses/LICENSE-2.0
- *
- * Unless required by applicable law or agreed to in writing, software
- * distributed under the License is distributed on an "AS IS" BASIS,
- * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
- * See the License for the specific language governing permissions and
- * limitations under the License.
- */
-
-package com.jsyn.unitgen;
-
-import com.jsyn.ports.UnitInputPort;
-import com.jsyn.ports.UnitOutputPort;
-
-/**
- * SchmidtTrigger unit.
- * <P>
- * Output logic level value with hysteresis. Transition high when input exceeds setLevel. Only go
- * low when input is below resetLevel. This can be used to reject low level noise on the input
- * signal. The default values for setLevel and resetLevel are both 0.0. Setting setLevel to 0.1 and
- * resetLevel to -0.1 will give some hysteresis. The outputPulse is a single sample wide pulse set
- * when the output transitions from low to high.
- *
- * <PRE>
- * if (output == 0.0)
- * output = (input &gt; setLevel) ? 1.0 : 0.0;
- * else if (output &gt; 0.0)
- * output = (input &lt;= resetLevel) ? 0.0 : 1.0;
- * else
- * output = previous_output;
- * </PRE>
- *
- * @author Phil Burk (C) 2009 Mobileer Inc
- * @see Compare
- */
-public class SchmidtTrigger extends UnitFilter {
- public UnitInputPort setLevel;
- public UnitInputPort resetLevel;
- public UnitOutputPort outputPulse;
-
- /* Define Unit Ports used by connect() and set(). */
- public SchmidtTrigger() {
- addPort(setLevel = new UnitInputPort("SetLevel"));
- addPort(resetLevel = new UnitInputPort("ResetLevel"));
- addPort(input = new UnitInputPort("Input"));
- addPort(outputPulse = new UnitOutputPort("OutputPulse"));
- }
-
- @Override
- public void generate(int start, int limit) {
- double[] inPtr = input.getValues();
- double[] pulsePtr = outputPulse.getValues();
- double[] outPtr = output.getValues();
- double[] setPtr = setLevel.getValues();
- double[] resetPtr = resetLevel.getValues();
-
- double outputValue = outPtr[0];
- boolean state = (outputValue > UnitGenerator.FALSE);
- for (int i = start; i < limit; i++) {
- pulsePtr[i] = UnitGenerator.FALSE;
- if (state) {
- if (inPtr[i] <= resetPtr[i]) {
- state = false;
- outputValue = UnitGenerator.FALSE;
- }
- } else {
- if (inPtr[i] > setPtr[i]) {
- state = true;
- outputValue = UnitGenerator.TRUE;
- pulsePtr[i] = UnitGenerator.TRUE; /* Single impulse. */
- }
- }
- outPtr[i] = outputValue;
- }
- }
-}